Multi-parameter Patient Monitor BD6000
Previous   Next

Multi-parameter Patient Monitor BD6000



BD6000 Multi-parameter patient monitor is applicable for hospitals to monitor such body features as ECG, non-invasive blood pressure, heart rate, pulse oxygen saturation, respiration, body temperature and so on


 


Able to measure in-phase 3-7-channel ECG, heart rate, respiration, temperature, pulse, blood oxygen saturation, non-invasive blood pressure and pulse transit time


 


12.1¡± TFT super-big screen, real color, wide-visual-angle and high-brightness display


 


Inbuilt with rechargeable, maintenance-free and high capacity batteries, able to work more than 2 hours without additional power supply


 


With the function of network, bed-side machines and central multi-parameter monitor system can form a monitor network 


 


Able to display trend data, manual printing and alarm trigger printing functions available


 


Able to use together with high-frequency electrotome and defibrillator



[Contact Information]

Posted by John Liu
e-MailThis information shows after Login.
Firm
JETEEM MEDICAL ELECTRONICS TECH CO.,LTD.
Address shenzhen, Guang dong province, China
City & ZIP
518055
Land
China
Telephone
This information shows after Login.

InterestPatient Monitor

Product Specifications
Technical Specifications
Size and weight
Size: 320mm¡Á270mm¡Á155mm£¨BD9000£©
345mm¡Á260mm¡Á168mm (BD6000)
Weight: 7.5 KG
Operating condition
Temperature range: Operating 0-45¡æ
Saving and transporting -20-60¡æ
Dampness range: Operating <=85%
Saving and transporting <=95%
Altitude range: Operating -500-4,600m
Saving and transporting -500-13,100m
Electrical specification: AC 100-250V 50/60 Hz, Max input power 60VA,Fuse T 0.5A
Specification of screen
True color,12.1¡±TFT type LCD, distinguish rate 800¡Á600
Signal interface
Interface of exterior display: Standard VGA
Exterior communication interface: RS422/RS485
Exterior printer interface: Standard combines
Record apparatus
Record width: 50mm
Paper feed speed: 25mm/s
Recording waveform: 3 ways
Record type: continuously real time record
Manually one time record
Time striking record
Alarm striking record
Trend saving
6 hours/1 second¡ª128 hours/1 minute
Specification of ECG
Lead mode: 12 leads (R,L,F,N,C1¡¢C2¡¢C3¡¢C4¡¢C5¡¢C6)
Method of Lead: ¢ñ¡¢¢ò¡¢¢ó¡¢aVR¡¢aVL¡¢aVF¡¢V1¡¢V2¡¢V3¡¢V4¡¢V5¡¢V6
Waveform of Lead: 12 ways
Gain: ¡Á0.5 ¡¢¡Á1¡¢¡Á2¡¢¡Á4
Mode: diagnoses mode, monitoring mode, and operating mode
Input resistance: >5 M¦¸
Coenelasma suppression ratio: >90dB
Polarization voltage range of electrode: ¡À300mV
Drain current: <30¦ÌA
Resuming time of base line: after defibrillation<3s
Range of ECG signal: ¡À10 mV (peak value)
Frequency response: Diagnoses mode 0.05-100Hz
Monitoring mode 0.5-40Hz
Operation mode 1-20Hz
Heart rate
Measuring range: 10-300 bmp
Measuring accuracy: ¡À1%
Definition: 1bpm
Sensitivity ratio: >0.2mV (peak value)
Respiration specification
Method: RA-LA resistance
Input the resistance: >2.5 M¦¸
Bandwidth: 0.1-2Hz
Respiration rate: 0-120 rpm
Measuring range: 0-120 rpm
Definition: 1 rpm
Sensitivity ratio: ¡À2 rpm
Specification of NIBP
Measuring method: method of shocking automatically
Operating mode: manual, periodic and continuous
Partition of periodic measure: 5,10,45,60 minutes
Continuous mode: 5 minutes
Range of pulse rate: 40-240 bpm
Measuring range:
Adult: Systolic pressure 25-255 mmHg
Diastolic pressure 10-220 mmHg
Mean pressure 15-235 mmHg
Child: Systolic pressure 20-135 mmHg
Diastolic pressure 10-110 mmHg
Mean pressure 15-125 mmHg
Definition: 1 mmHg
Sensitivity ratio: Max average error ¡À5 mmHg
Max standard error 8 mmHg
Overvoltage protection: Adult 290 mmHg
Child 145 mmHg
Specification of SPO2
Measuring range: 0-100%
Definition: 1%
Sensitivity ratio: 70-100% ¡À2%
40-69% ¡À3%
0-39% not explain
Refresh time: About a second
Alarm delay: 10 seconds
Pulse rate: Measuring range 0-254 bmp
Definition 1bmp
Sensitivity ratio ¡À2 bpm
Alarm delay 10 seconds
Specification of TEMP
Measuring range: 0¡æ-50¡æ
Definition 0.1¡æ
Sensitivity ratio: ¡À0.2¡æ
Refresh time: About a second
Average time constant: <10s



Industry Categorymedical equipment

Quality/Safety Certifications

Delivery Lead Timewithin 20 days

Payment & Price TermsFOB T/T

My Offerswelcome you to ask about it

Other ProductsPatient Monitor
fetal monitor
fetal doppler
pulse oximeter

Customersall over the world

Company History

Estimated Annual Sales

Company News

Remarks

Web SiteThis information shows after Login.

Product Details
Product id 26761
views  153
Added 2007.04.20
 

content

Products in this categoryMore productsContact nowSend to friendRate itPrint
Large picture


Copyright © 2007 Trade-World.org, The International Trade Associations