Trade-World / Chemical / Coatings
PRTV Outside the power equipment insulates with takes shape the permanence anti flashover the compou
Previous   Next

PRTV Outside the power equipment insulates with takes shape the permanence anti flashover the compou



PRTV Outside the power equipment insulates with takes shape the permanence anti flashover the compound coating

 

Outside the power equipment insulates with takes shape the permanence anti flashover the compound coating, Is one kind of electrical power system uses the new electrical function material, Is specially for the electrical network and each round, loses, uses electricity the customer to be lasting eliminates the equipment flashover thoroughly the hidden danger but to design; Develops jointly by the North China electric power academy of science with our company successfully. The product has the unique chemical composition and the structure, Achieved and surpasses the heat vulcanization silica gel physics electrical specification, Overall performance and so on more outstanding water repellency nature, As well as 20 years design service life has provided one kind of new technical measure for the electric porcelaneous equipment permanence counter- dirt.

2 Product execution qualification

This uses the North China electric power group company standard "Outside the Power equipment To insulate with Takes shape the Permanence Anti flashover the Compound Coating (PRTV) To use Leads Then", With Hebei silicon valley chemical industry limited company standard Q/HGH 019-2004 “Outside PRTV Power equipment Insulates with Takes shape Permanence Anti flashover Compound Coating" to organize the product the production and the construction.

3 Range of application

This product mainly uses in the electrical power system transformer substation and the transmission line insulator, the power plant and the electric power user changes outside the electricity equipment as well as other electrical equipments insulates lastingly anti flashover . After the porcelain (or glass) the insulator uses this product, Forms the porcelain (or glass) the skeleton complex effect, Enhances one kind of standardized disposition plan which outside the power transformer equipment insulates. Is suitable in alternating and direct circuit system rated voltage 1~750kV, Environment Temperature  -50℃~ +50℃, Under the contamination condition moves outside the transformer substation and the impractical transmission line equipment insulates antifouling, Prevention flashover, Enhances the equipment outside to insulate the rank.

4 Operation guide

To porcelain (or glass) insulator superficial thorough clear dirt, Removes the contamination, the fat and other attachments, After waits the electric porcelaneous surface pure to be dry, May use to spurt spreads or brushes spreads and so on to spread spreads the method to carry on the construction, Coating thickness is 0.5 ~ 0.6mm, the coating should leak proof spread, not dribble, does not hang the silk, The surface is smooth, levels also does not have the air bubble. Originally has used the RTV equipment, Should be clean the unreliable attachment cleaning up, remove the contamination, After uses the special-purpose processing medicinal preparation to clean, Again executes spreads PRTV.

 

5. Package and storage

This product packing in airtight metal container, When storing and transportation should maintain dry and ventilates, Prevented all day exposes to the sun, the rain drenches. The storage time is 1 year, Duplicate surpassed the storage time after to examine qualified still may use

When the coating uncaps the use, if has not used up, Should cover securely immediately the airtight preservation.

 

PRTV Outside the power equipment insulates with takes shape the permanence anti flashover the compound coating technology parameter data sheet











































































































































































































Items

Q/HGH 019-2004 Standard

Technical Property (Test)

Test method

Outward appearance;

Does not have the obvious mechanical impurity and the cotton wool shape, The coating should level, be smooth also does not have the air bubble

Toughness liquid, Does not have the impurity and the cotton wool shape, The coating is smooth also does not have the air bubble

GB 1721-1979

Viscosity            s

100~200

160

GB 1723-1993

Dielectric Strength  kV/mm

≮25

32.3

GB 1408-1978

Surface resistivity  Ω·m

Volume resistivity  Ω·m

≮1×1012

4.25×1013

GB 1410-1978

≮1×1014

2.92×1015

Relative permittivity dielectric lose tangent value

≯3.0

2.7

GB 1409-1978

≯0.3%

2.5×10-3

Arc resistance       s

≮180

217

GB 1411-1978

Bears leaks

The mark

And the

Electricity

Wear and

Tear

AC

Alternating

current

  ≮TMA 4.5

1A 4.5

GB 6553-1986

DC

Direct

Current

  ≮TMA 3.5

1A3.5

Adhesion ability

Cementation shearing strength   MPa

≮3.0

4.7

GB 13936-1992

Cycling method level

No less 2 level

1

GB1720-1989

Abrasion resistance  g

≯0.05

0.035

GB 1768-1989

Ratio of Water absorption        %

≯0.25

0.15

GB 1738-1989

Hydrophobicity

Hydrophobicity and level

Qav≥100°Qmin≥90°HC1~2

106°~109° HC1

DL/T810-2002

 

Lose property   96h

Qav≥90°Qmin≥85°HC3~4

Non showing loss

recovery characteristic

t≤24h

/

 

 

 

 

 

 

Water repellency characteristic  96h

Qav≥110°Q min≥100°HC2~3

14 h Hydrophobicity reach HC1

110°~115°

Erosion Resistance Test

Acid , alkali and salt , 80℃24 h

Does not have the corrugation, falls off, bubbles, changes color and so on, The adhesion is not lower than 2 levels

Does not have the corrugation, falls off, bubbles, changes color the phenomenon, The adhesion is 1 level

GB 1763-1989

transformer oil  105℃24 h

Does not have the corrugation, falls off, bubbles and so on, The adhesion is not lower than 2 levels

Does not have the corrugation, falls off, bubbles the phenomenon, The adhesion is 1 level

GB 1739-1989

 

 

 

Labor frequency arc-over voltage

Dry arc-over voltage kV

Has the coating insulator not to have the coating insulator not to have relatively to reduce

Paint-coat  79.2 , no 75.9

GB 775-1987

Wet arc-over voltage  kV

Paint-coat  61.9, no 55.9

Flashover resistance test

U1(have paint-coat )/U2(no paint-coat )≥2.0

U1 /U2 =2.23

GB 4585.1-1984

Heat resistant denaturation experiment -40℃~+80℃,2.5h×5 times

The coating should not damage, The adhesion inspection is not lower than 2 levels

After the experiment the coating does not have bubbles, the dehiscence, falls off, Adhesion 1 level

DL/T627-1997

Salt Spray test 1700 h

The test specimen does not surpass 3 time has flowed the severance

After 1800h,Does not have has flowed the severance

GBT5892-2003

GB/SV023-2003

Does not have leaks the mark, The electricity wear and tears have not  reached the porcelain glaze

Does not have leaks the mark, The wear and tears have not  reached the glazed surface

Hydrophobic migration characteristic HC2~3 level

HC1~2 level

A row line of experiment passes ≥3.0MPa

3.5 MPa

Flame Resistance

FV-O level

FV-O level

GB/T13488-92

The longitudinal strength and pulls apart the elongation ratio

Strength  MPa

≮4.0

5.5

GB/T528-1988

elongation %

No less 350

390

peel strength     kN/m

≮12.0

17.5

GB/T529-1988

Hardness         (邵氏)

35~55

46

GB/T531-1999

Sulficadion time 

Surface Dry up    min

20~50

35

GB6753.2-1986

Full dry up    h

≯72

65

storage stability     50℃

≥45days

After 60 days ,A row line of experiment passes

GB6753.3-1986

Self Clearance property  [Only requests antifouling]

After the dirty fluid cementation is dry, Strips the intensity ≯3kPa(1 level )

Peel off strength 2.3kPa(1 level )

QB/SV021-2003

Anti –icing property [Only requests to guard against the ice]

Anti- regelation (measure)

Paint-coat ice cover measure /no paint-coat ≯30%

18.3%

QB/SV022-2003

 Dehydration property

DC value ≮90%

91.2%


 


[Contact Information]

Posted by bo
e-MailThis information shows after Login.
Firm
Silicon Valley Chemical Co., Ltd
Address Guangfu,Yongnian,Handan , Hebei , China
City & ZIP
057151
Land
China
Telephone
This information shows after Login.

InterestPower Room Temperature Vulcanizing

Product SpecificationsPRTV Outside the power equipment insulates with takes shape the permanence anti flashover the compound coating

Outside the power equipment insulates with takes shape the permanence anti flashover the compound coating, Is one kind of electrical power system uses the new electrical function material, Is specially for the electrical network and each round, loses, uses electricity the customer to be lasting eliminates the equipment flashover thoroughly the hidden danger but to design; Develops jointly by the North China electric power academy of science with our company successfully. The product has the unique chemical composition and the structure, Achieved and surpasses the heat vulcanization silica gel physics electrical specification, Overall performance and so on more outstanding water repellency nature, As well as 20 years design service life has provided one kind of new technical measure for the electric porcelaneous equipment permanence counter- dirt.
2 Product execution qualification
This uses the North China electric power group company standard "Outside the Power equipment To insulate with Takes shape the Permanence Anti flashover the Compound Coating (PRTV) To use Leads Then", With Hebei silicon valley chemical industry limited company standard Q/HGH 019-2004 “Outside PRTV Power equipment Insulates with Takes shape Permanence Anti flashover Compound Coating" to organize the product the production and the construction.
3 Range of application
This product mainly uses in the electrical power system transformer substation and the transmission line insulator, the power plant and the electric power user changes outside the electricity equipment as well as other electrical equipments insulates lastingly anti flashover . After the porcelain (or glass) the insulator uses this product, Forms the porcelain (or glass) the skeleton complex effect, Enhances one kind of standardized disposition plan which outside the power transformer equipment insulates. Is suitable in alternating and direct circuit system rated voltage 1~750kV, Environment Temperature -50℃~ +50℃, Under the contamination condition moves outside the transformer substation and the impractical transmission line equipment insulates antifouling, Prevention flashover, Enhances the equipment outside to insulate the rank.
4 Operation guide
To porcelain (or glass) insulator superficial thorough clear dirt, Removes the contamination, the fat and other attachments, After waits the electric porcelaneous surface pure to be dry, May use to spurt spreads or brushes spreads and so on to spread spreads the method to carry on the construction, Coating thickness is 0.5 ~ 0.6mm, the coating should leak proof spread, not dribble, does not hang the silk, The surface is smooth, levels also does not have the air bubble. Originally has used the RTV equipment, Should be clean the unreliable attachment cleaning up, remove the contamination, After uses the special-purpose processing medicinal preparation to clean, Again executes spreads PRTV.

5. Package and storage
This product packing in airtight metal container, When storing and transportation should maintain dry and ventilates, Prevented all day exposes to the sun, the rain drenches. The storage time is 1 year, Duplicate surpassed the storage time after to examine qualified still may use
When the coating uncaps the use, if has not used up, Should cover securely immediately the airtight preservation.

PRTV Outside the power equipment insulates with takes shape the permanence anti flashover the compound coating technology parameter data sheet
Items Q/HGH 019-2004 Standard Technical Property (Test) Test method
Outward appearance; Does not have the obvious mechanical impurity and the cotton wool shape, The coating should level, be smooth also does not have the air bubble Toughness liquid, Does not have the impurity and the cotton wool shape, The coating is smooth also does not have the air bubble GB 1721-1979
Viscosity s 100~200 160 GB 1723-1993
Dielectric Strength kV/mm ≮25 32.3 GB 1408-1978
Surface resistivity Ω·m
Volume resistivity Ω·m ≮1×1012 4.25×1013 GB 1410-1978
≮1×1014 2.92×1015
Relative permittivity dielectric lose tangent value ≯3.0 2.7 GB 1409-1978
≯0.3% 2.5×10-3
Arc resistance s ≮180 217 GB 1411-1978
Bears leaks
The mark
And the
Electricity
Wear and
Tear AC
Alternating
current ≮TMA 4.5 1A 4.5 GB 6553-1986
DC
Direct
Current ≮TMA 3.5 1A3.5
Adhesion ability Cementation shearing strength MPa ≮3.0 4.7 GB 13936-1992
Cycling method level No less 2 level 1 GB1720-1989
Abrasion resistance g ≯0.05 0.035 GB 1768-1989
Ratio of Water absorption % ≯0.25 0.15 GB 1738-1989
Hydrophobicity Hydrophobicity and level Qav≥100°Qmin≥90°HC1~2 106°~109° HC1 DL/T810-2002

Lose property 96h Qav≥90°Qmin≥85°HC3~4 Non showing loss
recovery characteristic t≤24h /






Water repellency characteristic 96h Qav≥110°Q min≥100°HC2~3 14 h Hydrophobicity reach HC1
110°~115°
Erosion Resistance Test Acid , alkali and salt , 80℃24 h Does not have the corrugation, falls off, bubbles, changes color and so on, The adhesion is not lower than 2 levels Does not have the corrugation, falls off, bubbles, changes color the phenomenon, The adhesion is 1 level GB 1763-1989
transformer oil 105℃24 h Does not have the corrugation, falls off, bubbles and so on, The adhesion is not lower than 2 levels Does not have the corrugation, falls off, bubbles the phenomenon, The adhesion is 1 level GB 1739-1989



Labor frequency arc-over voltage Dry arc-over voltage kV Has the coating insulator not to have the coating insulator not to have relatively to reduce Paint-coat 79.2 , no 75.9 GB 775-1987
Wet arc-over voltage kV Paint-coat 61.9, no 55.9
Flashover resistance test U1(have paint-coat )/U2(no paint-coat )≥2.0 U1 /U2 =2.23 GB 4585.1-1984
Heat resistant denaturation experiment -40℃~+80℃,2.5h×5 times The coating should not damage, The adhesion inspection is not lower than 2 levels After the experiment the coating does not have bubbles, the dehiscence, falls off, Adhesion 1 level DL/T627-1997
Salt Spray test 1700 h The test specimen does not surpass 3 time has flowed the severance After 1800h,Does not have has flowed the severance GBT5892-2003
GB/SV023-2003
Does not have leaks the mark, The electricity wear and tears have not reached the porcelain glaze Does not have leaks the mark, The wear and tears have not reached the glazed surface
Hydrophobic migration characteristic HC2~3 level HC1~2 level
A row line of experiment passes ≥3.0MPa 3.5 MPa
Flame Resistance FV-O level FV-O level GB/T13488-92
The longitudinal strength and pulls apart the elongation ratio Strength MPa ≮4.0 5.5 GB/T528-1988
elongation % No less 350 390
peel strength kN/m ≮12.0 17.5 GB/T529-1988
Hardness (邵氏) 35~55 46 GB/T531-1999
Sulficadion time Surface Dry up min 20~50 35 GB6753.2-1986
Full dry up h ≯72 65
storage stability 50℃ ≥45days After 60 days ,A row line of experiment passes GB6753.3-1986
Self Clearance property [Only requests antifouling] After the dirty fluid cementation is dry, Strips the intensity ≯3kPa(1 level ) Peel off strength 2.3kPa(1 level ) QB/SV021-2003
Anti –icing property [Only requests to guard against the ice] Anti- regelation (measure) Paint-coat ice cover measure /no paint-coat ≯30% 18.3% QB/SV022-2003
Dehydration property DC value ≮90% 91.2%




Industry CategoryEletric Power transimission

Quality/Safety CertificationsISO9002

Delivery Lead Time2010

Payment & Price TermsCIF

My OffersPRTV Outside the power equipment insulates with takes shape the permanence anti flashover the compound coating

Outside the power equipment insulates with takes shape the permanence anti flashover the compound coating, Is one kind of electrical power system uses the new electrical function material, Is specially for the electrical network and each round, loses, uses electricity the customer to be lasting eliminates the equipment flashover thoroughly the hidden danger but to design; Develops jointly by the North China electric power academy of science with our company successfully. The product has the unique chemical composition and the structure, Achieved and surpasses the heat vulcanization silica gel physics electrical specification, Overall performance and so on more outstanding water repellency nature, As well as 20 years design service life has provided one kind of new technical measure for the electric porcelaneous equipment permanence counter- dirt.
2 Product execution qualification
This uses the North China electric power group company standard "Outside the Power equipment To insulate with Takes shape the Permanence Anti flashover the Compound Coating (PRTV) To use Leads Then", With Hebei silicon valley chemical industry limited company standard Q/HGH 019-2004 “Outside PRTV Power equipment Insulates with Takes shape Permanence Anti flashover Compound Coating" to organize the product the production and the construction.
3 Range of application
This product mainly uses in the electrical power system transformer substation and the transmission line insulator, the power plant and the electric power user changes outside the electricity equipment as well as other electrical equipments insulates lastingly anti flashover . After the porcelain (or glass) the insulator uses this product, Forms the porcelain (or glass) the skeleton complex effect, Enhances one kind of standardized disposition plan which outside the power transformer equipment insulates. Is suitable in alternating and direct circuit system rated voltage 1~750kV, Environment Temperature -50℃~ +50℃, Under the contamination condition moves outside the transformer substation and the impractical transmission line equipment insulates antifouling, Prevention flashover, Enhances the equipment outside to insulate the rank.
4 Operation guide
To porcelain (or glass) insulator superficial thorough clear dirt, Removes the contamination, the fat and other attachments, After waits the electric porcelaneous surface pure to be dry, May use to spurt spreads or brushes spreads and so on to spread spreads the method to carry on the construction, Coating thickness is 0.5 ~ 0.6mm, the coating should leak proof spread, not dribble, does not hang the silk, The surface is smooth, levels also does not have the air bubble. Originally has used the RTV equipment, Should be clean the unreliable attachment cleaning up, remove the contamination, After uses the special-purpose processing medicinal preparation to clean, Again executes spreads PRTV.

5. Package and storage
This product packing in airtight metal container, When storing and transportation should maintain dry and ventilates, Prevented all day exposes to the sun, the rain drenches. The storage time is 1 year, Duplicate surpassed the storage time after to examine qualified still may use
When the coating uncaps the use, if has not used up, Should cover securely immediately the airtight preservation.

PRTV Outside the power equipment insulates with takes shape the permanence anti flashover the compound coating technology parameter data sheet
Items Q/HGH 019-2004 Standard Technical Property (Test) Test method
Outward appearance; Does not have the obvious mechanical impurity and the cotton wool shape, The coating should level, be smooth also does not have the air bubble Toughness liquid, Does not have the impurity and the cotton wool shape, The coating is smooth also does not have the air bubble GB 1721-1979
Viscosity s 100~200 160 GB 1723-1993
Dielectric Strength kV/mm ≮25 32.3 GB 1408-1978
Surface resistivity Ω·m
Volume resistivity Ω·m ≮1×1012 4.25×1013 GB 1410-1978
≮1×1014 2.92×1015
Relative permittivity dielectric lose tangent value ≯3.0 2.7 GB 1409-1978
≯0.3% 2.5×10-3
Arc resistance s ≮180 217 GB 1411-1978
Bears leaks
The mark
And the
Electricity
Wear and
Tear AC
Alternating
current ≮TMA 4.5 1A 4.5 GB 6553-1986
DC
Direct
Current ≮TMA 3.5 1A3.5
Adhesion ability Cementation shearing strength MPa ≮3.0 4.7 GB 13936-1992
Cycling method level No less 2 level 1 GB1720-1989
Abrasion resistance g ≯0.05 0.035 GB 1768-1989
Ratio of Water absorption % ≯0.25 0.15 GB 1738-1989
Hydrophobicity Hydrophobicity and level Qav≥100°Qmin≥90°HC1~2 106°~109° HC1 DL/T810-2002

Lose property 96h Qav≥90°Qmin≥85°HC3~4 Non showing loss
recovery characteristic t≤24h /






Water repellency characteristic 96h Qav≥110°Q min≥100°HC2~3 14 h Hydrophobicity reach HC1
110°~115°
Erosion Resistance Test Acid , alkali and salt , 80℃24 h Does not have the corrugation, falls off, bubbles, changes color and so on, The adhesion is not lower than 2 levels Does not have the corrugation, falls off, bubbles, changes color the phenomenon, The adhesion is 1 level GB 1763-1989
transformer oil 105℃24 h Does not have the corrugation, falls off, bubbles and so on, The adhesion is not lower than 2 levels Does not have the corrugation, falls off, bubbles the phenomenon, The adhesion is 1 level GB 1739-1989



Labor frequency arc-over voltage Dry arc-over voltage kV Has the coating insulator not to have the coating insulator not to have relatively to reduce Paint-coat 79.2 , no 75.9 GB 775-1987
Wet arc-over voltage kV Paint-coat 61.9, no 55.9
Flashover resistance test U1(have paint-coat )/U2(no paint-coat )≥2.0 U1 /U2 =2.23 GB 4585.1-1984
Heat resistant denaturation experiment -40℃~+80℃,2.5h×5 times The coating should not damage, The adhesion inspection is not lower than 2 levels After the experiment the coating does not have bubbles, the dehiscence, falls off, Adhesion 1 level DL/T627-1997
Salt Spray test 1700 h The test specimen does not surpass 3 time has flowed the severance After 1800h,Does not have has flowed the severance GBT5892-2003
GB/SV023-2003
Does not have leaks the mark, The electricity wear and tears have not reached the porcelain glaze Does not have leaks the mark, The wear and tears have not reached the glazed surface
Hydrophobic migration characteristic HC2~3 level HC1~2 level
A row line of experiment passes ≥3.0MPa 3.5 MPa
Flame Resistance FV-O level FV-O level GB/T13488-92
The longitudinal strength and pulls apart the elongation ratio Strength MPa ≮4.0 5.5 GB/T528-1988
elongation % No less 350 390
peel strength kN/m ≮12.0 17.5 GB/T529-1988
Hardness (邵氏) 35~55 46 GB/T531-1999
Sulficadion time Surface Dry up min 20~50 35 GB6753.2-1986
Full dry up h ≯72 65
storage stability 50℃ ≥45days After 60 days ,A row line of experiment passes GB6753.3-1986
Self Clearance property [Only requests antifouling] After the dirty fluid cementation is dry, Strips the intensity ≯3kPa(1 level ) Peel off strength 2.3kPa(1 level ) QB/SV021-2003
Anti –icing property [Only requests to guard against the ice] Anti- regelation (measure) Paint-coat ice cover measure /no paint-coat ≯30% 18.3% QB/SV022-2003
Dehydration property DC value ≮90% 91.2%




Other Products

CustomersPRTV Outside the power equipment insulates with takes shape the permanence anti flashover the compound coating

Outside the power equipment insulates with takes shape the permanence anti flashover the compound coating, Is one kind of electrical power system uses the new electrical function material, Is specially for the electrical network and each round, loses, uses electricity the customer to be lasting eliminates the equipment flashover thoroughly the hidden danger but to design; Develops jointly by the North China electric power academy of science with our company successfully. The product has the unique chemical composition and the structure, Achieved and surpasses the heat vulcanization silica gel physics electrical specification, Overall performance and so on more outstanding water repellency nature, As well as 20 years design service life has provided one kind of new technical measure for the electric porcelaneous equipment permanence counter- dirt.
2 Product execution qualification
This uses the North China electric power group company standard "Outside the Power equipment To insulate with Takes shape the Permanence Anti flashover the Compound Coating (PRTV) To use Leads Then", With Hebei silicon valley chemical industry limited company standard Q/HGH 019-2004 “Outside PRTV Power equipment Insulates with Takes shape Permanence Anti flashover Compound Coating" to organize the product the production and the construction.
3 Range of application
This product mainly uses in the electrical power system transformer substation and the transmission line insulator, the power plant and the electric power user changes outside the electricity equipment as well as other electrical equipments insulates lastingly anti flashover . After the porcelain (or glass) the insulator uses this product, Forms the porcelain (or glass) the skeleton complex effect, Enhances one kind of standardized disposition plan which outside the power transformer equipment insulates. Is suitable in alternating and direct circuit system rated voltage 1~750kV, Environment Temperature -50℃~ +50℃, Under the contamination condition moves outside the transformer substation and the impractical transmission line equipment insulates antifouling, Prevention flashover, Enhances the equipment outside to insulate the rank.
4 Operation guide
To porcelain (or glass) insulator superficial thorough clear dirt, Removes the contamination, the fat and other attachments, After waits the electric porcelaneous surface pure to be dry, May use to spurt spreads or brushes spreads and so on to spread spreads the method to carry on the construction, Coating thickness is 0.5 ~ 0.6mm, the coating should leak proof spread, not dribble, does not hang the silk, The surface is smooth, levels also does not have the air bubble. Originally has used the RTV equipment, Should be clean the unreliable attachment cleaning up, remove the contamination, After uses the special-purpose processing medicinal preparation to clean, Again executes spreads PRTV.

5. Package and storage
This product packing in airtight metal container, When storing and transportation should maintain dry and ventilates, Prevented all day exposes to the sun, the rain drenches. The storage time is 1 year, Duplicate surpassed the storage time after to examine qualified still may use
When the coating uncaps the use, if has not used up, Should cover securely immediately the airtight preservation.

PRTV Outside the power equipment insulates with takes shape the permanence anti flashover the compound coating technology parameter data sheet
Items Q/HGH 019-2004 Standard Technical Property (Test) Test method
Outward appearance; Does not have the obvious mechanical impurity and the cotton wool shape, The coating should level, be smooth also does not have the air bubble Toughness liquid, Does not have the impurity and the cotton wool shape, The coating is smooth also does not have the air bubble GB 1721-1979
Viscosity s 100~200 160 GB 1723-1993
Dielectric Strength kV/mm ≮25 32.3 GB 1408-1978
Surface resistivity Ω·m
Volume resistivity Ω·m ≮1×1012 4.25×1013 GB 1410-1978
≮1×1014 2.92×1015
Relative permittivity dielectric lose tangent value ≯3.0 2.7 GB 1409-1978
≯0.3% 2.5×10-3
Arc resistance s ≮180 217 GB 1411-1978
Bears leaks
The mark
And the
Electricity
Wear and
Tear AC
Alternating
current ≮TMA 4.5 1A 4.5 GB 6553-1986
DC
Direct
Current ≮TMA 3.5 1A3.5
Adhesion ability Cementation shearing strength MPa ≮3.0 4.7 GB 13936-1992
Cycling method level No less 2 level 1 GB1720-1989
Abrasion resistance g ≯0.05 0.035 GB 1768-1989
Ratio of Water absorption % ≯0.25 0.15 GB 1738-1989
Hydrophobicity Hydrophobicity and level Qav≥100°Qmin≥90°HC1~2 106°~109° HC1 DL/T810-2002

Lose property 96h Qav≥90°Qmin≥85°HC3~4 Non showing loss
recovery characteristic t≤24h /






Water repellency characteristic 96h Qav≥110°Q min≥100°HC2~3 14 h Hydrophobicity reach HC1
110°~115°
Erosion Resistance Test Acid , alkali and salt , 80℃24 h Does not have the corrugation, falls off, bubbles, changes color and so on, The adhesion is not lower than 2 levels Does not have the corrugation, falls off, bubbles, changes color the phenomenon, The adhesion is 1 level GB 1763-1989
transformer oil 105℃24 h Does not have the corrugation, falls off, bubbles and so on, The adhesion is not lower than 2 levels Does not have the corrugation, falls off, bubbles the phenomenon, The adhesion is 1 level GB 1739-1989



Labor frequency arc-over voltage Dry arc-over voltage kV Has the coating insulator not to have the coating insulator not to have relatively to reduce Paint-coat 79.2 , no 75.9 GB 775-1987
Wet arc-over voltage kV Paint-coat 61.9, no 55.9
Flashover resistance test U1(have paint-coat )/U2(no paint-coat )≥2.0 U1 /U2 =2.23 GB 4585.1-1984
Heat resistant denaturation experiment -40℃~+80℃,2.5h×5 times The coating should not damage, The adhesion inspection is not lower than 2 levels After the experiment the coating does not have bubbles, the dehiscence, falls off, Adhesion 1 level DL/T627-1997
Salt Spray test 1700 h The test specimen does not surpass 3 time has flowed the severance After 1800h,Does not have has flowed the severance GBT5892-2003
GB/SV023-2003
Does not have leaks the mark, The electricity wear and tears have not reached the porcelain glaze Does not have leaks the mark, The wear and tears have not reached the glazed surface
Hydrophobic migration characteristic HC2~3 level HC1~2 level
A row line of experiment passes ≥3.0MPa 3.5 MPa
Flame Resistance FV-O level FV-O level GB/T13488-92
The longitudinal strength and pulls apart the elongation ratio Strength MPa ≮4.0 5.5 GB/T528-1988
elongation % No less 350 390
peel strength kN/m ≮12.0 17.5 GB/T529-1988
Hardness (邵氏) 35~55 46 GB/T531-1999
Sulficadion time Surface Dry up min 20~50 35 GB6753.2-1986
Full dry up h ≯72 65
storage stability 50℃ ≥45days After 60 days ,A row line of experiment passes GB6753.3-1986
Self Clearance property [Only requests antifouling] After the dirty fluid cementation is dry, Strips the intensity ≯3kPa(1 level ) Peel off strength 2.3kPa(1 level ) QB/SV021-2003
Anti –icing property [Only requests to guard against the ice] Anti- regelation (measure) Paint-coat ice cover measure /no paint-coat ≯30% 18.3% QB/SV022-2003
Dehydration property DC value ≮90% 91.2%




Company History

Estimated Annual Sales

Company News

Remarks

Web SiteThis information shows after Login.

Product Details
Product id 20342
views  326
Added 2006.07.28
 

content

Products in this categoryMore productsContact nowSend to friendRate itPrint


Copyright © 2007 Trade-World.org, The International Trade Associations