    PRTV outside power equipment insulates with takes shape permanence anti flashover compound coating,
is a kind of electrical power system uses the new electrical function
material, it¡¯s specially for the electrical network and each round,
loses, uses electricity the customer to be lasting eliminates the
equipment flashover thoroughly the hidden danger then to design, It¡¯s
developed jointly by the North China electric power academy of science
with our company successfully. The product has the unique chemical
composition and the structure, achieved and surpasses the heat
vulcanization silicon rubber physics electrical specification, Overall
performance and so on more outstanding water repellency nature, as well
as 20 years design service life has provided a kind of new technical
measure for the electric porcelaneous equipment permanence counter-
dirt.

    1.     Product Execution Qualification

This uses
the North China electric power group company standard "Outside the
Power equipment To insulate with Takes shape the Permanence Anti
flashover the Compound Coating (PRTV) To use Leads Then", With Hebei
silicon valley chemical industry limited company standard Q/HGH
019-2004 ¡°Outside PRTV Power equipment Insulates with Takes shape
Permanence Anti flashover Compound Coating" to organize the product the
production and the construction.

    2.     Range of application

This product
mainly uses in the electrical power system transformer substation and
the transmission line insulator, the power plant and the electric power
user changes outside the electricity equipment as well as other
electrical equipments insulates lastingly anti flashover . After the
porcelain (or glass) the insulator uses this product, Forms the
porcelain (or glass) the skeleton complex effect, Enhances one kind of
standardized disposition plan which outside the power transformer
equipment insulates. Is suitable in alternating and direct circuit
system rated voltage 1~750kV, Environment Temperature -50¡æ~ +50¡æ, Under
the contamination condition moves outside the transformer substation
and the impractical transmission line equipment insulates antifouling,
Prevention flashover, Enhances the equipment outside to insulate the
rank.

    3.     Operation Guide

To porcelain
(or glass) insulator superficial thorough clear dirt, Removes the
contamination, the fat and other attachments, After waits the electric
porcelaneous surface pure to be dry, May use to spurt spreads or
brushes spreads and so on to spread spreads the method to carry on the
construction, Coating thickness is 0.5 ~ 0.6mm, the coating should leak
proof spread, not dribble, does not hang the silk, The surface is
smooth, levels also does not have the air bubble. Originally has used
the RTV equipment, Should be clean the unreliable attachment cleaning
up, remove the contamination, After uses the special-purpose processing
medicinal preparation to clean, Again executes spreads PRTV.

     4.     Package and Storage

This product
packing in airtight metal container, When storing and transportation
should maintain dry and ventilates, Prevented all day exposes to the
sun, the rain drenches. The storage time is 1 year, Duplicate surpassed
the storage time after to examine qualified still may use when the
coating uncaps the use, if has not used up, Should cover securely
immediately the airtight preservation.

 

 

 

PRTV outside power equipment insulates with takes shape permanence anti flashover compound coating Technology parameter data sheet

 









































































































































































































Items

Q/HGH 019-2004 Standard

Technical Property £¨Test£©

Test method

Outward appearance

 

Does not
have the obvious mechanical impurity and the cotton wool shape, The
coating should level, be smooth also does not have the air bubble

Toughness liquid, Does not have the impurity and the cotton wool shape, The coating is smooth also does not have the air bubble

GB 1721-1979

Viscosity            s

100~200

160

GB 1723-1993

Dielectric Strength  kV/mm

¡Ú25

32.3

GB 1408-1978

Surface resistivity  ¦¸¡¤m

Volume resistivity  ¦¸¡¤m

¡Ú1¡Á1012

4.25¡Á1013

GB 1410-1978

¡Ú1¡Á1014

2.92¡Á1015

Relative permittivity dielectric lose tangent value

¡Û3.0

2.7

GB 1409-1978

¡Û0.3%

2.5¡Á10-3

Arc resistance       s

¡Ú180

217

GB 1411-1978

Electricity wear and tear leaks

AC

Alternating current

  ¡ÚTMA 4.5

1A 4.5

GB 6553-1986

DC

Direct current

  ¡ÚTMA 3.5

1A3.5

Adhesion ability

Cementation shearing strength   MPa

¡Ú3.0

4.7

GB 13936-1992

Cycling method level

No less 2 level

1

GB1720-1989

Abrasion resistance  g

¡Û0.05

0.035

GB 1768-1989

Ratio of Water absorption        %

¡Û0.25

0.15

GB 1738-1989

Hydrophobicity

Hydrophobic

and level

Qav¡Ý100¡ãQmin¡Ý90¡ãHC1~2

106¡ã~109¡ã HC1

DL/T810-2002

Lose property   96h

Qav¡Ý90¡ãQmin¡Ý85¡ãHC3~4

Non showing loss

recovery characteristic

t¡Ü24h

 

Water repellency characteristic  96h

Qav¡Ý110¡ãQ min¡Ý100¡ãHC2~3

14 h Hydrophobicity reach HC1  110¡ã~115¡ã

Erosion Resistance Test

Acid , alkali and salt , 80¡æ24 h

Does not have the corrugation, falls off, bubbles, changes color and so on, The adhesion is not lower than 2 levels

Does not have the corrugation, falls off, bubbles, changes color the phenomenon, The adhesion is 1 level

GB 1763-1989

transformer oil  105¡æ24 h

Does not have the corrugation, falls off, bubbles and so on, The adhesion is not lower than 2 levels

Does not have the corrugation, falls off, bubbles the phenomenon, The adhesion is 1 level

GB 1739-1989

Labor frequency arc-over voltage

Dry arc-over voltage kV

Has the coating insulator not to have the coating insulator not to have relatively to reduce

Paint-coat  79.2 , no 75.9

GB 775-1987

Wet arc-over voltage  kV

Paint-coat  61.9, no 55.9

Flashover resistance test

U1(have paint-coat )/U2(no paint-coat )¡Ý2.0

U1 /U2 =2.23

GB 4585.1-1984

Heat resistant denaturation experiment -40¡æ~+80¡æ£¬2.5h¡Á5 times

The coating should not damage, The adhesion inspection is not lower than 2 levels

After the experiment the coating does not have bubbles, the dehiscence, falls off, Adhesion 1 level

DL/T627-1997

Salt Spray test 1700 h

The test specimen does not surpass 3 time has flowed the severance

After 1800h£¬Does not have has flowed the severance

GBT5892-2003

GB/SV023-2003

Does not have leaks the mark, The electricity wear and tears have not  reached the porcelain glaze

Does not have leaks the mark, The wear and tears have not  reached the glazed surface

Hydrophobic migration characteristic HC2~3 level

HC1~2 level

A row line of experiment passes ¡Ý3.0MPa

3.5 MPa

Flame Resistance

FV-O level

FV-O level

GB/T13488-92

The longitudinal strength and pulls apart the elongation ratio

Strength  MPa

¡Ú4.0

5.5

GB/T528-1988

elongation %

No less 350

390

peel strength     kN/m

¡Ú12.0

17.5

GB/T529-1988

Hardness         (Shao )

35~55

46

GB/T531-1999

Vulcanizing time

Surface Dry up    min

20~50

35

GB6753.2-1986

Full dry up  h

¡Û72

65

storage stability     50¡æ

¡Ý45days

After 60 days £¬A row line of experiment passes

GB6753.3-1986

Self Clearance property  [Only requests antifouling]

After the dirty fluid cementation is dry, Strips the intensity ¡Û3kPa(1 level )

Peel off strength 2.3kPa(1 level )

QB/SV021-2003

Anti ¨Cicing property [Only requests to guard against the ice]

Anti- regelation (measure)

Paint-coat ice cover measure /no paint-coat ¡Û30%

18.3%

QB/SV022-2003

hydration property

DC value ¡Ú90%

91.2%







 












[Contact Information]

Posted by Sharry Chen
e-MailThis information shows after Login.
Firm
Hebei Silicon Valley chemical 73 Co., Ltd
Address NO.5 Century Boulevard, Handan
City & ZIP
Handan 056001
Land
Hebei China
Telephone
This information shows after Login.

Interestanti flashover compound coating

Product Specificationsit is a kind of electrical power system uses the new electrical function material, it¡¯s specially for the electrical network and each round, loses, uses electricity the customer to be lasting eliminates the equipment flashover thoroughly the hidden danger then to design, It¡¯s developed jointly by the North China electric power academy of science with our company successfully.

Industry Categorycoating

Quality/Safety Certifications

Delivery Lead Time10 day

Payment & Price TermsT/T

My Offers1

Other Products

CustomersChina, North America, Western Europe, Eastern Europe, Mid East

Company History

Estimated Annual Sales

Company News

Remarks

Web SiteThis information shows after Login.

Product Details
Product id 30500
views  104
Added 2007.09.21
 

content

Products in this categoryMore productsContact nowSend to friendRate itPrint
Large picture


Copyright © 2007 Trade-World.org, The International Trade Associations